Datasets:
robocollect/so-101-6
A LeRobot dataset for the so101_new_calib, built by DataForge from human demonstration video. 15 episodes, 10152 frames at 30 fps.
Columns
| Column | What it is |
|---|---|
observation.images.top |
The operator's video, re-encoded |
observation.state |
Joint positions in the robot's dataset units (its URDF's angles), the gripper in its own values |
action |
The commanded joint positions, same units |
12 values, left_arm_shoulder_pan.pos … right_arm_gripper.pos, robot type bi_so101_follower: the left arm is the hand that worked on the left of the picture, and both arms share one clock.
Each robot is read from its own URDF: no calibration file. The gripper runs
between the robot's own dataset values for open and closed.
How it was made
Nobody teleoperated a robot to record this. Each episode is a phone video of a
person doing the task with their own hand, retargeted onto the so101_new_calib by
hand2robot-1.0: a 3D hand reconstruction, then
differential IK onto its URDF, then retiming inside its joints' speed
limits.
Episodes are on the robot's clock, which runs about 1.6 to 2 times slower than the human's, so video frames repeat where the arm moves slowly. The travel to and from the calibration pose is not included.
Only clips that passed both an automatic content check and a trajectory quality gate are here. The gate rejects, among other things, clips where the manipulated object was tracked in too few frames, where too much of the hand path lies outside the arm's reach.
What to know before you train on it
observation.stateis not measured. It is the previous commanded position: the IK trajectory, assuming the servos track it perfectly. No physical robot executed these trajectories.- The gripper closes when the object is held, timed from the steps the automatic check named ("pick up ...", "place ..."). A hand around an object keeps thumb and index apart, so it is not read off the fingers. Episodes whose steps do not say follow the thumb-index distance.
- The geometry is uncalibrated. The camera focal length is approximated from the frame size and the hand scale is a population average, so expect a few centimetres of absolute error.
- 0 of 15 episodes were solved against a real
lerobot-calibratefile. Episodes without one assume symmetric joint ranges: fine to train on, wrong to replay on a particular arm. - Open loop. The object is where the video said it was. A real arm needs the same layout relative to its base, or its own perception.
- Downloads last month
- 91