"""Bench racks (2026-10-23: a real-model bench rack for the 20 mL headspace vials, inventory type `vial_rack_20ml`).
* labware.mn_702503_vial_rack_23mm - MACHEREY-NAGEL vial rack 702503 (36 positions, alpha-numeric index, max. vial diameter 23.1 mm,
323 x 91 x 30 mm, blue polypropylene, stackable when empty; the same 36-position 23.1 mm rack is sold as WHEATON/DWK 064088 and
Restek 22643). It holds the Agilent 20 mL headspace vial (O 22.75 mm, labware.agilent_hs_vial_20ml).
The maker does not publish the hole pitch: the 3 x 12 grid is laid out evenly inside a 3 mm rim (26.42 x 28.33 mm, assumption);
deck height, floor and stacking pins follow the product photo.
* Robot access (Franka Hand, top-down): fingers close along Y. The finger sizes come from the franka_description collision mesh
(fingertip 17.8 mm wide x 16.4 mm thick over its last 19 mm, finger base 21 x 26.2 mm from 24 mm above the tip; tip 8.9 mm below
the TCP). At 26.42 mm pitch the fingers do not fit between neighbours along the closing direction, so only rows A and C are robot
slots (24) and row B stays empty (manual use only); the finger clearance to every occupied neighbour is computed here.
"""
from __future__ import annotations
import math
import numpy as np
import trimesh
from labware_kit import FRANKA_MAX_GRASP_M, HAND_ABOVE_TCP_M, LabwareAsset, Link, Prim, frame
from sources import SOURCES as _GLOBAL_SOURCES
SRC = {
"mn_702503": {"kind": "manufacturer",
"reference": "MACHEREY-NAGEL vial rack REF 702503 product page "
"(https://www.mn-net.com/Vial-racks-max.-diameter-23.1-mm-36-pos.-stackable-if-empty-702503)",
"locator": "Technical data: positions 36, alpha-numerical index, dimensions L x W x H 323 x 91 x 30 mm, polypropylene (PP), blue, "
"stackable (only when empty), maximal vial diameter 23 mm / for headspace vials with a diameter of 23.1 mm, 5 pieces per pack; "
"product photo 6506_702503 (3 rows x 12 holes, raised rim, stacking pins at the corners and mid sides)",
"note": "Real model of the bench rack for 20 mL headspace vials.", "licence": "facts"},
"dwk_064088": {"kind": "manufacturer",
"reference": "DWK Life Sciences WHEATON 36-Position Rack for 23.1 mm Open ID, cat. 064088 "
"(https://www.thermofisher.com/order/catalog/product/kr/en/064088; Fisher 11571325)",
"locator": "36 positions, 23.1 mm open ID, for 6/10/20 mL headspace 23 mm OD vials; 12.6 x 3.5 x 1.12 in (320 x 89 x 28 mm)",
"note": "Same rack design from a second supplier (corroborates the footprint and the hole size).", "licence": "facts"},
"restek_22643": {"kind": "manufacturer", "reference": "Restek vial storage rack cat. 22643 (https://www.restek.com/p/22643)",
"locator": "polypropylene rack for 6, 10 or 20 mL headspace vials, holds up to 36, autoclavable 121 C 20 min",
"note": "Same 36-position headspace-vial rack class.", "licence": "facts"},
"franka_finger": {"kind": "code", "reference": "franka_description (Franka Emika, Apache-2.0): meshes/collision/finger.stl, hand.stl, panda_arm_hand.urdf "
"(copy shipped with the Isaac Sim URDF importer)",
"locator": "finger.stl: last 19 mm 17.8 mm wide (x) x 16.4 mm thick (closing axis); base part 21 x 26.2 mm from 24 mm above the tip; "
"length 53.9 mm; panda_finger_joint 0..0.04 m; hand_tcp 0.1034 m -> fingertip end 8.9 mm below the TCP; "
"hand.stl 63 x 204 x 92 mm, lowest point 37 mm above the TCP",
"note": "Finger and hand sizes for the clearance check.", "licence": "Apache-2.0"},
"rack_assumption": {"kind": "assumption", "reference": "MN 702503 details not in the data sheet", "locator": "engineering value",
"note": "Hole pitch not published: 12 x 3 cells laid out evenly inside a 3 mm rim of the documented 323 x 91 mm footprint "
"(26.42 x 28.33 mm); deck top 22 mm (3 mm thick) 4 mm below the rim top (26 mm), 2 mm floor, six 3 x 4 mm stacking pins "
"on the rim (30 mm overall) after the product photo; mass = modelled PP volume x 905 kg/m3.",
"licence": "n/a"},
"robot_access": _GLOBAL_SOURCES["robot_access"],
}
for _k, _v in SRC.items():
_GLOBAL_SOURCES.setdefault(_k, _v)
PP_BLUE = (0.09, 0.20, 0.62, 1.0)
PP_RHO = 905.0
# Franka finger / hand (franka_description collision meshes)
FINGER_TIP = {"width": 0.0178, "thick": 0.0165, "z0": 0.0, "z1": 0.019} # z above the fingertip end
FINGER_BASE = {"width": 0.021, "thick": 0.0262, "z0": 0.024, "z1": 0.0539}
TIP_BELOW_TCP = 0.0089
VIAL_D, VIAL_H = 0.02275, 0.0775 # Agilent 20 mL headspace vial (labware.agilent_hs_vial_20ml, with cap)
VIAL_GRASP_Z = 0.0445 # its grasp frame above the vial bottom
OPEN_W = 0.031 # finger opening for the approach (4.1 mm per side around the vial)
def _cell_grid(L=0.323, W=0.091, rim=0.003, nx=12, ny=3):
px, py = (L - 2 * rim) / nx, (W - 2 * rim) / ny
xs = [-(L - 2 * rim) / 2 + px * (i + 0.5) for i in range(nx)]
ys = [-(W - 2 * rim) / 2 + py * (j + 0.5) for j in range(ny)]
return px, py, xs, ys
def finger_clearance(target, occupied, w=OPEN_W, seat_z=0.002) -> dict:
"""Smallest XY gap between the Franka fingers (closing along Y, top-down) around the vial in `target` and the occupied neighbours."""
tcp_z = seat_z + VIAL_GRASP_Z
tip_z = tcp_z - TIP_BELOW_TCP
v0, v1 = seat_z, seat_z + VIAL_H
worst = (1.0, None)
for part in (FINGER_TIP, FINGER_BASE):
z0, z1 = tip_z + part["z0"], tip_z + part["z1"]
if z1 < v0 or z0 > v1:
continue
for s in (-1, 1):
y_in, y_out = target[1] + s * w / 2, target[1] + s * (w / 2 + part["thick"])
ylo, yhi = min(y_in, y_out), max(y_in, y_out)
xlo, xhi = target[0] - part["width"] / 2, target[0] + part["width"] / 2
for n in occupied:
if abs(n[0] - target[0]) < 1e-9 and abs(n[1] - target[1]) < 1e-9:
continue
dx = max(xlo - n[0], 0.0, n[0] - xhi)
dy = max(ylo - n[1], 0.0, n[1] - yhi)
gap = math.hypot(dx, dy) - VIAL_D / 2
if gap < worst[0]:
worst = (gap, [round(n[0], 5), round(n[1], 5)])
return {"min_gap_m": round(worst[0], 5), "nearest_vial_m": worst[1], "hand_bottom_above_vial_tops_m": round(tcp_z + HAND_ABOVE_TCP_M - (seat_z + VIAL_H), 5)}
def build_vial_rack_23mm() -> LabwareAsset:
L, W, H = 0.323, 0.091, 0.030
rim, rim_top, deck_top, deck_t, floor_t, hole_d = 0.003, 0.026, 0.022, 0.003, 0.002, 0.0231
px, py, xs, ys = _cell_grid(L, W, rim)
rows = ["A", "B", "C"]
a = LabwareAsset("mn_702503_vial_rack_23mm", "labware.mn_702503_vial_rack_23mm",
"MACHEREY-NAGEL 顶空瓶架 702503(36 位,孔径 23.1 mm,PP 蓝)", "MACHEREY-NAGEL vial rack 702503, 36 positions, max. vial O 23.1 mm",
"racks", "labware.rack.vial", "passive",
description_zh="MN 702503 顶空瓶架:36 位(3 行 × 12 列,字母数字索引),外形 323×91×30 mm,蓝色聚丙烯,空架可叠放;放 O23 mm 的 6/10/20 mL "
"顶空瓶(Agilent 20 mL 顶空瓶 O22.75 mm)。同款 36 位 23.1 mm 架另有 WHEATON 064088、Restek 22643。"
"孔距厂家未公布:在 3 mm 边框内均分(26.42×28.33 mm,假设)。机器人(Franka 俯抓、手指沿 Y 合拢)只用 A、C 两行 24 位,B 行留空。",
sources={k: _GLOBAL_SOURCES[k] for k in SRC})
# deck with 36 holes (visual by boolean), rim, floor, pins
deck = trimesh.creation.box([L - 2 * rim, W - 2 * rim, deck_t])
deck.apply_translation([0, 0, deck_top - deck_t / 2])
cutters = []
for y in ys:
for x in xs:
c = trimesh.creation.cylinder(radius=hole_d / 2, height=deck_t * 3, sections=40)
c.apply_translation([x, y, deck_top - deck_t / 2])
ch = trimesh.creation.cone(radius=hole_d / 2 + 0.0012, height=0.0024, sections=40) # 1.2 mm entry chamfer (photo: rounded hole edges)
ch.apply_transform(trimesh.transformations.rotation_matrix(math.pi, [1, 0, 0]))
ch.apply_translation([x, y, deck_top + 0.0012])
cutters += [c, ch]
deck_v = deck.difference(trimesh.util.concatenate(cutters))
walls = [Prim("box", [L, rim, rim_top], [0, -(W - rim) / 2, rim_top / 2]), Prim("box", [L, rim, rim_top], [0, (W - rim) / 2, rim_top / 2]),
Prim("box", [rim, W - 2 * rim, rim_top], [-(L - rim) / 2, 0, rim_top / 2]), Prim("box", [rim, W - 2 * rim, rim_top], [(L - rim) / 2, 0, rim_top / 2])]
floor = Prim("box", [L - 2 * rim, W - 2 * rim, floor_t], [0, 0, floor_t / 2])
pin_xy = [(sx * (L / 2 - 0.006), sy * (W / 2 - 0.0015 - 0.0)) for sx in (-1, 1) for sy in (-1, 1)] + [(0.0, -(W / 2 - 0.0015)), (0.0, W / 2 - 0.0015)]
pins = [Prim("cylinder", [0.0015, H - rim_top], [x, y, rim_top + (H - rim_top) / 2]) for x, y in pin_xy]
# deck collision: border strips + strips between the holes (square openings of the hole diameter)
deck_c = []
gx, gy = px - hole_d, py - hole_d
zc = deck_top - deck_t / 2
for i in range(len(xs) + 1): # strips between columns (along Y)
x = (xs[0] - px / 2) + i * px
wx = gx / 2 if i in (0, len(xs)) else gx
cx = x + (wx / 2 if i == 0 else -wx / 2 if i == len(xs) else 0.0)
deck_c.append(Prim("box", [wx, W - 2 * rim, deck_t], [cx, 0.0, zc]))
for j in range(len(ys) + 1): # strips between rows (along X)
y = (ys[0] - py / 2) + j * py
wy = gy / 2 if j in (0, len(ys)) else gy
cy = y + (wy / 2 if j == 0 else -wy / 2 if j == len(ys) else 0.0)
deck_c.append(Prim("box", [L - 2 * rim, wy, deck_t], [0.0, cy, zc]))
solid = walls + [floor] + pins
vis = [(deck_v, PP_BLUE)] + [(trimesh.util.concatenate([p.mesh() for p in solid]), PP_BLUE, {"name": "frame"})]
vol = float(deck_v.volume) + sum(p.mesh().volume for p in solid)
a.add(Link("body", "瓶架(边框、孔板、底板)", "竖直承放 36 个 O23 mm 顶空瓶;空架可叠放",
"注塑聚丙烯托盘:3 行 × 12 列孔(O23.1 mm),孔板低于边框 4 mm,四角与长边中点有叠放销",
visual=vis, collision=walls + [floor] + deck_c + pins, mass_kg=vol * PP_RHO, mass_evidence="assumption",
mass_note_zh=f"建模 PP 体积 {vol * 1e6:.0f} cm3 × 905 kg/m3(厂家未公布质量)", material="pp", geometry_evidence="documented",
geometry_note_zh="外形 323×91×30 mm、36 位、孔径 23.1 mm 按 MN 数据;孔距、孔板高度、底板与叠放销为假设/照片估计"))
# robot slots: rows A and C (fingers close along Y); row B manual only
robot_rows = ["A", "C"]
occupied = [(x, ys[rows.index(r)]) for r in robot_rows for x in xs]
clear = [finger_clearance((x, ys[rows.index(r)]), occupied) for r in robot_rows for x in xs]
worst = min(clear, key=lambda c: c["min_gap_m"])
clear_b = finger_clearance((xs[5], ys[0]), [(x, y) for y in ys for x in xs]) # if row B were filled too
fr = {}
for r in robot_rows:
y = ys[rows.index(r)]
for i, x in enumerate(xs):
name = f"{r}{i + 1:02d}"
seat = [x, y, floor_t]
tcp = [x, y, floor_t + VIAL_GRASP_Z]
a.ports.append({"name": name, "place_id": "vial_rack_20ml", "part": "body", "kind": "storage", "position_m": [round(v, 5) for v in seat],
"insert_axis": [0.0, 0.0, -1.0], "capture_m": 0.01, "radius_m": round(hole_d / 2, 5), "moves_with": "body",
"headroom_m": None, "required_free_above_vial_top_m": 0.25, "fits": ["headspace_vial_20ml", "vial"],
"access": ["franka_top_down"],
"vial_grasp_tcp_m": [round(v, 5) for v in tcp], "vial_grasp_rot_xyzw": [1.0, 0.0, 0.0, 0.0], "finger_axis": [0.0, 1.0, 0.0],
"approach_open_width_m": OPEN_W,
"note_zh": "顶空瓶瓶底中心(孔底);俯抓 TCP = 瓶 grasp(瓶底上 44.5 mm),手指沿 Y 合拢、张开 31 mm;架上方须留 ≥0.25 m 空间"})
fr[f"slot_{name}"] = frame(seat, "base_link", rot=[0.0, 0.0, 0.0, 1.0], note_zh=f"{name} 位:瓶底中心")
a.labware = {"type_id": a.asset_type_id, "family": "rack", "labware_class": "vial_rack", "fits": ["bench"],
"maker": "MACHEREY-NAGEL", "model": "Vial rack, max. diameter 23.1 mm, 36 positions, stackable if empty (blue PP)", "catalogue_no": "702503",
"also_sold_as": ["DWK WHEATON 064088", "Restek 22643 (36-position rack for 6/10/20 mL headspace vials)"],
"holds": "labware.agilent_hs_vial_20ml", "positions_total": 36, "grid": {"rows": rows, "columns": 12, "pitch_x_m": round(px, 5), "pitch_y_m": round(py, 5),
"hole_diameter_m": hole_d, "pitch_evidence": "assumption (not published)"},
"frames": fr, "seat_z_m": floor_t, "deck_top_m": deck_top, "franka_grasp_ok": False,
"franka_blocked_reason": "91 mm wide (> 74 mm grip): the rack stays on the bench; the robot moves the vials",
"storage": {"place_ids": ["vial_rack_20ml"], "min_pitch_m": math.floor(px * 1e5) / 1e5 - 1e-5, "expected_positions": [p["name"] for p in a.ports],
"robot_rows": robot_rows, "manual_only_rows": ["B"], "required_free_above_vial_top_m": 0.25,
"note_zh": "A、C 两行 24 位给机器人;B 行留空(手指沿 Y 合拢时会碰到 B 行的瓶)"},
"robot_access": {"gripper": "Franka Hand", "approach": "top-down", "finger_axis": [0.0, 1.0, 0.0], "approach_open_width_m": OPEN_W,
"max_grasp_width_m": FRANKA_MAX_GRASP_M, "vial_diameter_m": VIAL_D, "vial_height_with_cap_m": VIAL_H,
"finger_tip_m": FINGER_TIP, "finger_base_m": FINGER_BASE, "tip_below_tcp_m": TIP_BELOW_TCP,
"min_finger_gap_rows_A_C_m": worst["min_gap_m"], "nearest_vial_m": worst["nearest_vial_m"],
"hand_bottom_above_vial_tops_m": worst["hand_bottom_above_vial_tops_m"],
"min_finger_gap_if_row_B_filled_m": clear_b["min_gap_m"],
"fingertip_end_above_deck_m": round(floor_t + VIAL_GRASP_Z - TIP_BELOW_TCP - deck_top, 5),
"free_space_above_vial_tops_m": 0.25,
"note_zh": "手指尺寸取 franka_description 碰撞网格;A、C 行全部装满时,手指与最近的瓶最小间隙见 min_finger_gap_rows_A_C_m;"
"若 B 行也放瓶,手指会压到 B 行(间隙为负)。手掌底面高于瓶盖顶。架上方需 ≥0.25 m 空间(放在台面或开放层板上)。",
"source_ids": ["franka_finger", "robot_access"]}}
a.prop("body", "size_m", [L, W, H], "m", "外形 L×W×H(MN 702503)", "documented", ["mn_702503"])
a.prop("body", "positions", 36, "1", "孔位数(3 行 × 12 列,字母数字索引)", "documented", ["mn_702503"])
a.prop("body", "hole_diameter_m", hole_d, "m", "孔径(最大瓶径 23.1 mm)", "documented", ["mn_702503", "dwk_064088"])
a.prop("body", "pitch_m", [round(px, 5), round(py, 5)], "m", "孔距 X×Y:厂家未公布,按外形在 3 mm 边框内均分", "assumption", ["rack_assumption"])
a.prop("body", "deck_top_m", deck_top, "m", "孔板顶面高(照片估计:低于边框 4 mm)", "photo_estimate", ["mn_702503", "rack_assumption"])
a.prop("body", "material", "polypropylene, blue", "1", "材料与颜色", "documented", ["mn_702503"])
a.limitations_zh = ["孔距、孔板高度、底板和叠放销尺寸厂家未公布:孔距按外形均分(26.42×28.33 mm),其余按产品照片估计。",
"孔径 23.1 mm 与瓶径 22.75 mm 只差 0.35 mm:仿真里放瓶按 touch + intent 吸附到槽位(capture 10 mm),不靠接触求解插入。",
"机器人只用 A、C 两行(24 位);B 行留空,否则手指沿 Y 合拢时会碰到 B 行的瓶。架子本身 91 mm 宽,不由机器人搬运。"]
return a